Product


561000

Laryngeal mask

212000

Aerosol DrainageBag

131000
Manual suction pump
511000
Tracheal tube
521000
Tracheostomy tube
641000
Yankauer suction handle

700000

3-way stopcock

731000
Extension sets

411000

Oxygen mask

421000

Nebulizer
431000

Face mask with cushion

441000

Tracheostomy masks

432000

CPR pocket mask
622000

Oxygen connecting tube
621000

Nasal oxygen cannula
321000
Manual resuscitator
631000

Suction catheter with controlvalve
313000
Laryngoscope
541000
Breathing system
312000

CVP manometer scale



Microinrusionpump

Accessories



2007.PDF

    

Microinfusion pump

 

WZ-50C66T

1. Designed according to the latest IEC standard for syringe infusion pump
2. Flow rate increments: 0.01ml/h
3. Show syringe brand in the main infusion interface
4. Match 13 kinds of diffirent syringe brands
5. Syringe size: 10ml,20ml,30ml and 50/60ml
6. Recognize syringe size automatically
7. Full history log: drug delivered log within one week, infusion volume log within one month, inquiry include drug name, drug   volume, solution volume, remained infusion time, drug consistence, start time and end time
8. Alarm company with word prompt in the main infusion interface, which let you know the reason of alarm at a glance
9. Large size of LED
10.Four diffirent infusion mode: normal, body weight mode without drug name, body weight mode with drug name, drug selected but no body weight mode.
11.Marked red alarm light, which can be seen as far as 10m, bring you more safety.
12.Indicate the system pressure dynamic.
13.Anti bolus, bring you more safety
14.Three levels of system pressure: L,M,H
15.Ten diffirent of drug segment:                        174 kinds of drug names
16.Alarm: Near Empty, Empty, Bolus volume finished, OCCLUSION, infusion not smoothly,syringe disengaged, syringe dislocated, over flow rate range,main power error, low battery, battery empty, malfunction, reminder alarm, Repeat alarm, over dose rate range
17.Bolus volume range: 0.01ml to 9999ml, 0.1mg to 9999mg
18.all kinds of flow rate unit: ml/h,g/h,mg/h,g/min,ml/min,mg/min,ug/min,ug/h,wu/h,g/kg/h,mg/kg/h,ug/kg/h,g/kg/min,mg/kg/min,
ug/kg/min,ng/kg/min
19.KVO rate
20.Precision:±2%

                                        WZ-50C6T
1. Designed according to IEC standard, and get CE certificate from TUV.
2. Body Weight Mode.
   Dose Rate:      0.01 to 99.99ug/kg/min
                             0.01 to 99.99mg/kg/h
   Body Weight:    0.1 to 300kg
   Drug Volume:    0.1 to 999mg
   Solution Volume:0.1 to 999ml
3. KVO rate.
4. Anti Bolus.
5. Match as many as 13 kinds of diffirent syringe brands.
6. Syringe size: 20ml,30ml,50/60ml.
7. Alarm: Syringe dislocated, syringe disengaged, near empty, empty, OCCLUSION, VTBI finished, Main power failure,  Low battery, Battery empty, Reminder, Repeat

                                          WZ-50C6
1. Designed according to IEC standard, and get CE certificate from TUV.
2. KVO rate.
3. Anti Bolus.
4. Match as many as 13 kinds of diffirent syringe brands.
5. Syringe size: 20ml,30ml,50/60ml.
6. Alarm: Syringe dislocated, syringe disengaged, near empty, empty, OCCLUSION, VTBI finished, Main power failure, Low battery, Battery empty, Reminder, Repeat

                                            WZS-50F6
1. Designed according to IEC standard, and get CE certificate from TUV.
2. KVO rate.
3. Anti Bolus.
4. Match as many as 13 kinds of diffirent syringe brands.
5. Syringe size: 10ml,20ml,30ml,50/60ml.
6. Two channel with two governer. More economy and save space.
7. Alarm: Syringe dislocated, syringe disengaged, near empty, empty, OCCLUSION, VTBI finished, Main power failure, Low battery, Battery empty, Reminder, Repeat

 


E-mail: kyoling@kyoling.com